MODEL | LPV-20-5 | LPV-20-12 | LPV-20-15 | LPV-20-24 |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V |
RATED CURRENT | 3A | 1.67A | 1.33A | 0.84A |
CURRENT RANGE | 0 ~ 3A | 0 ~ 1.67A | 0 ~ 1.33A | 0 ~ 0.84A |
RATED POWER | 15W | 20W | 20W | 20.2W |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
VOLTAGE TOLERANCE Note.3 | ±5.0% |
LINE REGULATION | ±1.0% |
LOAD REGULATION | ±2.0% |
SETUP, RISE TIME Note.6 | 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at fullload |
HOLD UP TIME (Typ.) | 50ms/230VAC 16ms/115VAC at full load |
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 77% | 81% | 83% | 83% |
AC CURRENT | 0.55A/115VAC 0.35A/230VAC |
INRUSH CURRENT (max.) | COLD START 35A/115VAC 70A/230VAC |
LEAKAGE CURRENT | 0.25mA / 240VAC |
PROTECTION | OVER CURRENT Note.4 | 110 ~ 150% rated output power |
Protection type: Hiccup mode, recovers automatically after faultcondition is removed |
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16V | 17.5 ~ 21V | 28 ~ 32V |
Protection type: Shut off o/p voltage, clamping by zenerdiode |
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Zaxes |
SAFETY & EMC | SAFETY STANDARDS | Design refer to TUV EN60950-1, UL879, UL1310 Class 2, CAN/CSAC22.2 No. 223-M91 |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC |
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25℃ / 70% RH |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A,EN61000-3-3 |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industrylevel, criteria A |
OTHERS | MTBF | 786.5Khrs min. MIL-HDBK-217F (25℃ ) |
DIMENSION | 118*35*26mm (L*W*H) |
PACKING | 0.22Kg; 60pcs/14.2Kg/0.62CUFT |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VACinput, rated load and 25℃ of ambient temperature. 2. Ripple & noise aremeasured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated witha 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set uptolerance, line regulation and load regulation. 4. Derating may be neededunder low input voltage. Please check the derating curve for more details. 5.The power supply is considered a component which will be installed a finalequipment. The final equipment must be re-confirmed that it still meets EMCdirectives. 6. Length of set up time is measured at first cold start. TurningON/OFF the power supply may lead to increase of the set up time. 7. The unitmight not be suitable for lighing applications in EU countries. Please checkwith your local authorities for the possible use of the unit. 8. Suitable forindoor use or outdoor use without direct sunlight exposure. Please avoid immersein the water over 30minute. |