WENZHOU MINGWEI AUTOMATION SYSTEM CO.,LTD.
|
Price: | 7.7~10.7 USD |
Payment Terms: | T/T,L/C,WU |
Place of Origin: | Zhejiang, China (Mainland) |
![]() |
|
Add to My Favorites | |
HiSupplier Escrow |
MODEL | T-40A | T-40B | T-40C | |||||||
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | |
RATED CURRENT | 3A | 2A | 0.5A | 3A | 2A | 0.5A | 3A | 1.5A | 0.5A | |
CURRENT RANGE | 0.6 ~ 5A | 0.2 ~ 3A | 0.1 ~ 1A | 0.6 ~ 5A | 0.2 ~ 3A | 0.1 ~ 1A | 0.6 ~ 5A | 0.2 ~ 2A | 0.1 ~ 1A | |
RATED POWER | 41.5W | 45W | 45W | |||||||
RIPPLE & NOISE (max.) Note.2 | 100 mVp-p | 120 mVp-p | 100 mVp-p | 100 mVp-p | 120 mVp-p | 120 mVp-p | 100 mVp-p | 120 mVp-p | 120 mVp-p | |
VOLTAGE ADJ. RANGE | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | CH1: 4.75 ~ 5.5V | |||||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±6.0% | ±8.0% | ±2.0% | ±6.0% | ±8.0% | ±2.0% | ±6.0% | ±6.0% | |
LINE REGULATION | ±0.5% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% | ±0.5% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±0.5% | ±4.0% | ±6.0% | ±0.5% | ±4.0% | ±6.0% | ±0.5% | ±4.0% | ±4.0% | |
SETUP, RISE, HOLD TIME | 800ms, 50ms, 70ms/230VAC1600ms, 50ms,16ms/115VAC at fullload | |||||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC120 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ.) | 72%/115VAC | 72%/115VAC | 72%/115VAC | |||||||
AC CURRENT | 1.2A/115VAC0.7A/230VAC | |||||||||
INRUSH CURRENT (max.) | COLD START 20A/115VAC40A/230VAC | |||||||||
LEAKAGE CURRENT | <3.5mA / 240VAC | |||||||||
PROTECTION | OVERLOAD | 105 ~ 150% rated output power. | ||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed. | ||||||||||
OVER VOLTAGE | CH1: 5.75 ~ 6.75V | |||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed. | ||||||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to CSA 60950-1, (UL60950-1, IEC60950-1, TUV EN60950-1) | ||||||||
WITHSTAND VOLTAGE | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | |||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A | |||||||||
OTHERS | MTBF | 305.6K hrs min. MIL-HDBK-217F (25ºC) | ||||||||
DIMENSION | 129*98*38mm (L*W*H) | |||||||||
PACKING | 0.39Kg; 45pcs/19.6Kg/0.0326CMB | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºCof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |