WENZHOU MINGWEI AUTOMATION SYSTEM CO.,LTD.
|
Price: | 12.6~17.4 USD |
Payment Terms: | T/T,L/C,WU |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
MODEL | SD-25A-5 | |
OUTPUT | DC VOLTAGE | 5V |
RATED CURRENT | 5A | |
CURRENT RANGE | 0 ~ 5A | |
RATED POWER | 25W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5VDC | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE, HOLD TIME | 2.5s, 50ms,--- at full load | |
INPUT | VOLTAGE RANGE | 9.2 ~ 18VDC |
EFFICIENCY (Typ.) | 71% | |
DC CURRENT | 3.2A/12V | |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power |
Protection type : Fold back current limiting, recovers automatically afterfault condition is removed | ||
OVER VOLTAGE | 5.75 ~ 6.75V/10% load | |
Protection type: Hiccup mode, recovers automatically after fault conditionis removed | ||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY & EMC (Note 4) | SAFETY STANDARDS | Design refer to LVD |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |
EMI CONDUCTION & RADIATION | Design refer to EN55022(CISPR22) CLASS B | |
EMS IMMUNITY | Design refer to EN61000-4-2,3,4,6,8;ENV50204,EN55024,light industry level,criteria A | |
OTHERS | MTBF | 374.3K hrs min. MIL-HDBK-217F (25ºC ) |
DIMENSION | 99*97*36mm (L*W*H) | |
PACKING | 0.38Kg; 45pcs/17.8Kg/0.9CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured atnormal input, rated load and 25ºC of ambient temperature. 2. Ripple &noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wireterminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includesset up tolerance, line regulation and load regulation. 4. The power supply isconsidered a component which will be installed into final equipment. The finalequipment must be re-confirmed that it still meets EMC directives. |