WENZHOU MINGWEI AUTOMATION SYSTEM CO.,LTD.
|
Price: | 13.9~19.3 USD |
Payment Terms: | T/T,L/C,WU |
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
MODEL | S-150-7.5 | |
OUTPUT | DC VOLTAGE | 7.5V |
RATED CURRENT | 20A | |
CURRENT RANGE | 0 ~ 20A | |
RATED POWER | 150W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | |
VOLTAGE ADJ. RANGE | 6 ~ 8.3V | |
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE, HOLD TIME | 100ms, 50ms at full load | |
HOLD TIME(Typ.) | 28ms at full load | |
INPUT | VOLTAGE RANGE | 88 ~ 132VAC/176 ~ 264VAC selected by switch248 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ.) | 80% | |
AC CURRENT | 3.2A/115VAC1.6A/230VAC | |
INRUSH CURRENT (max.) | COLD START 35A | |
LEAKAGE CURRENT | <3.5mA / 240VAC | |
PROTECTION | OVERLOAD | 105 ~ 150% rated output power |
Protection type: Shut down o/p voltage, re-power on to recover. | ||
OVER VOLTAGE | 8.63 ~ 10.13V | |
Protection type: Shut down o/p voltage, re-power on to recover. | ||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY & EMC(Note.4) | SAFETY STANDARDS | Design refer to UL1012, UL60950-1, TUV EN60950-1 |
WITHSTAND VOLTAGE | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | |
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A | |
OTHERS | MTBF | 286.7K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 199*110*50mm (L*W*H) | |
PACKING | 0.76Kg; 16pcs/13.7Kg/0.0287CMB | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12"twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |