ac to dc 12v
Price: |
10.4~14.4 USD |
Payment Terms: |
T/T,L/C,WU |
Place of Origin: |
Zhejiang, China (Mainland) |
Product Detail
Model No.:
S-145-12
Production Capacity:
30000 Pieces / Month
Delivery Date:
7 ~ 15 Days
Output Type:
Single
Brand Name:
INTMW
Output Frequency:
N/A
Dimension:
199*98*38mm (L*W*H)
Color:
Silver
Safety Compliance:
EMC & LVD
Input Frequency:
50 / 60Hz
Means of Transport:
Ocean,Air
Packing:
0.68Kg; 30pcs/22.3Kg/0.0250...
Input Voltage:
220V
Output Power:
101 - 200W
Output Voltage:
12V
Output Current:
12A
Certificate:
CE, RoHS
Shell Material:
Aluminum & Iron
Weight:
0.68Kg
145W AC to DC 12V S-145-12
1) INPUT: 110 ~ 230VAC 2) CE RoHS Approved
3) DIMENSION: 199*98*38mm (L*W*H) 4) 1 Year Warranty
145W AC to DC 12V S-145-12
Features:
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25 KHz
LED indicator for power on
Made in China for low cost
High reliability
1 year warranty
145W AC to DC 12V S-145-12 SpecificationMODEL | S-145-12 |
OUTPUT | DC VOLTAGE | 12V |
RATED CURRENT | 12A |
CURRENT RANGE | 0 ~ 12A |
RATED POWER | 144W |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p |
VOLTAGE ADJ. RANGE | 10.6 ~ 13.2V |
VOLTAGE TOLERANCE Note.3 | ±1.0% |
LINE REGULATION | ±0.5% |
LOAD REGULATION | ±0.5% |
SETUP, RISE, HOLD TIME | 100ms, 50ms, 24ms at full load |
INPUT | VOLTAGE RANGE | 85 ~ 132VAC/176 ~ 264VAC selected by switch248 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
EFFICIENCY (Typ.) | 80.5% |
AC CURRENT | 2.6A/115VAC1.3A/230VAC |
INRUSH CURRENT (max.) | COLD START 32A |
LEAKAGE CURRENT | <3.5mA / 240VAC |
PROTECTION | OVER LOAD | 125 ~ 165% rated output power |
Protection type: Shut down o/p voltage, re-power on to recover. |
OVER VOLTAGE | 13.8 ~ 16.2V |
Protection type: Shut down o/p voltage, re-power on to recover. |
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC | SAFETY STANDARDS | Design refer to UL1012 |
WITHSTAND VOLTAGE | I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION | Compliance to EN55022(CISPR22)Class B |
EMS IMMUNITY | Compliance to IEC801,2,3,4 Light industry level, Criteria A |
OTHERS | MTBF | 286.7K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION | 199*98*38mm (L*W*H) |
PACKING | 0.68Kg; 30pcs/22.3Kg/0.0250CMB |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. |
145W AC to DC 12V S-145-12 Mechanical Specification:
145W AC to DC 12V S-145-12 Certificate for LVD:
S-145-12 Certificate for EMC: